 Product Specification:       

Green Earth Fuel Protection System

(Tank/Tote/Drum Mounted)

Features & Benefits:

 

* Automatically maintains the fuel temperature at 40°F within an

   outdoor fuel storage tank, tote or drum.   

* Simple to install … spin it on, plug in the power and turn it on!

* B100 Biofuel compatible … only steel, aluminum and Viton within

   the fluid path.

* A single unit will protect up to 330 gallons of Biofuel or diesel fuel

   within an outdoor storage tank, tote or drum.

* Eliminates the need for expensive, ineffective pour point additives.

* Eliminate the need to cut with kerosene during the coldest months.

* Eliminate those “no heat” service calls due to fuel gelling on the

   coldest nights.

 

Specifications:

 

Model numbers: 

 

TSSHU400 (hard wired)

 

TSSHU400P (pluggable)

 

Input power:       115 VAC 50/60 Hz

 

Input power connection:

 

For TSSHU400: 14-18 Gauge Weatherproof Whip

For TSSHU400P: 14-18 Gauge Weatherproof Cord

 

Fuel tank/drum connection: 2” NPT Female (std)

 

Temperature sensor: 40°F set point

 

Mechanical Information: Overall size:

6” Diameter x 12” H

Weight: 8.5 lbs.

Mounting:  2” NPT Male

 

Maximum Operating

Environmental Conditions: -25°F to +85°F

@ 0% to 90% RH

 

Optional:

 

Temperature sensor set points: 50°F, 60°F

 

Fuel tank/tote/drum connection: 1-1/2” and 3” NPT Male

What’s inside and how does it work?

The new Thermal Stability Systems Green Earth fuel protection system installs directly into your tank, tote or drum.  After the unit is direct wired or plugged in, the unit is activated by a single lighted switch.  Once the unit is activated, the unit begins to operate the pump to determine the temperature of the stored fuel with the use of the immersion fuel sensor.  After the pump has operated for approximately one minute, the time/temperature controller will read the fuel temperature from the immersion fuel sensor.  If the fuel temperature is below 40°F, the unit continues to operate the pump and silicone heater until the immersion fuel sensor determines that the fuel temperature has reached 40°F.  If the time/temperature controller has determined that the fuel temperature is above 40°F, the unit shuts down for approximately one hour and then automatically begins to operate the pump unit for one minute to determine the fuel temperature.  This cycle continues automatically to protect your stored fuel.

What’s inside?

1 - 400W silicone laminate heater

2 - Immersion fuel temperature sensor

3 - Time/Temperature electronic controller

4 - Fuel pump

5 - 3/8” Female NPT supply/return connections

6 - Vents

7 - Weatherproof, lighted on/off switch

8 - High temperature safety thermostat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Information Request Form

Select the items that apply, and then let us know how to contact you.

Send product literature
Send company literature
Have a salesperson contact me

Name
Title
Company
Address
E-mail
Phone

 

Send mail to ehermsen@thermalstabilitysystems.com with questions or comments about this web site.
Last modified: 01/09/10